Figure 4-26.
CAM Components
j. Nozzle Protective Cap Assembly.
Protects nozzle assembly and ensures that clean air is sampled when
CAM is started (Figure 4-27).
k. Nozzle Assembly.
Chemical agent vapors are drawn in through this inlet for analysis by
the CAM (Figure 4-27).
l. Battery.
Lithium-sulfur dioxide battery powers the CAM (Figure 4-27).
WARNING
Individual cells within the battery contain lithium, sulfur
dioxide, and an electrolyte. Lithium reacts vigorously
with water or moist air. Sulphur dioxide is an irritant
gas and the electrolyte is flammable and highly corrosive.
A mishandled battery may explode or vent, release dangerous
fumes, and burn. Do not crush or burn battery. Do not
attempt to recharge batteries. A battery does not present
a hazard to personnel unless it is mishandled or misused.
Dispose of a battery in accordance with unit SOP.
IS0345
4-30